تعداد نشریات | 418 |
تعداد شمارهها | 10,005 |
تعداد مقالات | 83,623 |
تعداد مشاهده مقاله | 78,424,851 |
تعداد دریافت فایل اصل مقاله | 55,450,283 |
A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach | ||
journal of Artificial Intelligence in Electrical Engineering | ||
مقاله 3، دوره 1، شماره 2، آذر 2012، صفحه 17-28 اصل مقاله (1.37 M) | ||
چکیده | ||
This paper presents a novel method to calculate the reference source current and the reference compensating current for shunt active power filters (SAPFs). This method first calculates the amplitude and phase of the fundamental load current from a recursive algebraic approach block before calculating the displacement power factor. Next, the amplitude of the reference mains current is computed with the corresponding phase voltage. Finally, the difference between the actual load current and the reference source current is considered the reference compensating current to be delivered by the SAPF. The proposed method is presented and applied to the control system of the voltage source converter of SAPFs. The performance of the proposed method in reducing harmonics and improving the power factor is examined with a SAPF simulation model. The results are compared with the instantaneous active and reactive p-q power theory as other reference generation method. | ||
کلیدواژهها | ||
Power Quality؛ p-q theory؛ recursive algebraic approach؛ reference source current؛ shunt active power filter | ||
مراجع | ||
[1] A. Bhattacharya, C. Chakraborty, “A shunt active power filter with enhanced performance using ANN-based predictive and adaptive controllers,” IEEE Trans. Ind. Electron., vol. 58, no. 2, pp. 421–428,Feb. 2011. [2] S. Rahmani, N. Mendalek, and K. Al-Haddad, “Experimental design of a nonlinear control technique for three-phase shunt active power filter,”IEEE Trans. Ind. Electron., vol. 57, no. 10, pp. 3364–3375, Oct. 2010. [3] S.H. Fathi, M. Pishvaei, and G.B. Gharehpetian, “A frequency domain method for instantaneous determination of reference current in shunt active filter,” TENCON, IEEE Region 10 Conference,1-4, 2006. [4] Z. Salam, P. C. Tan, and A. Jusoh, “Harmonics mitigation using active power filter: A technological review,” Elektrika Journal of Electrical Engineering, 8: 17-26, 2006. [5] T. Komrska, J. Zák, and Z. Peroutka,“Control strategy of active power filter with adaptive FIR filter-based and DFT-based reference estimation,” Power Electronics Electrical Drives Automation and Motion (SPEEDAM), 2010 International Symposium on, Page(s): 1524 – 1529, 2010. [6] G. Chen, Y. Jiang, and H. Zhou, “Practical Issues of Recursive DFT in Active Power Filter Based on CPC Power Theory, “Power and Energy Engineering Conference, APPEEC 2009. Asia-Pacific, Page(s): 1 – 5, 2009. [7] H. Akagi, Yoshihira Kanazawa, and Akira Nabae,“Instantaneous Reactive Power Compensators Comprising Switching Devices Without Energy Storage Components, ” IEEE Transactions On Industry Applications, Vol. IA20, No.3, May/June1998. [8] M.A Kabir, U. Mahbub,“ Synchronous Detection and Digital control of Shunt Active Power Filter in Power Quality Improvement,” IEEE Power and Energy Conference at Illinois (IEEE PECI), University of Illinois at Urbana- Champaign, USA, 2011. [9] A. Khoshkbar Sadigh, M. Farasat, S.M. Barakati,“Active power filter with new compensation principle based on synchronous reference frame,” North America Power Symposium (NAPS),DOI: 10.1109/NAPS.2009.5484077,2009. [10] B.S. Kumar, K.R. Reddy, V. Lalitha,“PI, fuzzy logic controlled shunt active power filter for three-phase four-wire systems with balanced, unbalanced and variable loads,” Journal of Theoretical and Applied Information Technology 23 (2), pp. 122-130 0 ,2011. [11] A. Peiravi, R. Ildarabadi ,“Recursive algebraic method of computing power system harmonics,” IEEJ Transactions on Electrical and Electronic Engineering Volume 6, Issue 4, pages 338–344, July 2011. [12] B. Berbaoui , C.Benachaiba,“Power Quality Enhancement using Shunt Active Power Filter Based on Particle Swarm Optimization,” Journal of Applied Sciences, 11: 3725-3731, 2011. [13] H.Akagi, Y.Kanazawa and N.Nabae,”Generalized theory of the instantaneous reactive power in three-phase circuits”, in Proc. Int. Power El. Conf., pp 1375-1386, Tokyo, Japan, 1983 [14] G. Bhuvaneswari, M.G. Nair, “Design, Simulation, and Analog Circuit Implementation of a Three-Phase Shunt Active Filter Using the I cos Algorithm,” Power Delivery, IEEE Transactions on, Volume23, Issue: 2, Page(s): 1222 – 1235, 2008. [15] P. Karuppanan , K. K. Mahapatra , “PLL with PI, PID and Fuzzy Logic Controllers based Shunt Active Power Line Conditioners,” IEEE International Conference on Power Electronics, Drives and Energy Systems-Dec 21 o 23, 2010. [16] L. A. Zadeh, “The concept of a linguistic variable and its application to approximate reasoning-1,” Inf. Sci., vol. 8, pp. 199-249, 1975. [17] J.M. Mendel, Uncertain Rule-Based Fuzzy Logic: Introduction and new directions, Prentice Hall, USA, (2000). [18] J.M. Mendel, R.I. John and F. Liu, “ Interval type-2 fuzzy logic systems made simple”, IEEE Trans. Fuzzy Syst., 14: 808-821. 2006. [19] P . Karuppanan , K. K. Mahapatra , “PI and fuzzy logic controllers for shunt active power filter — A report,” ISA Transactions vol. 51 | ||
آمار تعداد مشاهده مقاله: 640 تعداد دریافت فایل اصل مقاله: 270 |