تعداد نشریات | 418 |
تعداد شمارهها | 9,997 |
تعداد مقالات | 83,560 |
تعداد مشاهده مقاله | 77,801,290 |
تعداد دریافت فایل اصل مقاله | 54,843,920 |
The Electrochemical Sensor for Selective Solid Phase Extraction of Pseudoephedrine Hydrochloride in a Real Sample | ||
Journal of Applied Chemical Research | ||
دوره 15، شماره 1، فروردین 2021، صفحه 8-23 اصل مقاله (900.73 K) | ||
نوع مقاله: Research Paper | ||
نویسندگان | ||
Morteza Omidinejad1؛ Mohammad Alimoradi* 1؛ Majid Ramezani1؛ Sattar Ebrahimi2 | ||
1Department of Chemistry, Faculty of Science, Arak Branch, Islamic Azad University, Arak, Iran | ||
2Department of Chemistry, Malayer Branch, Islamic Azad University, Malayer, Iran | ||
چکیده | ||
In the current study, a new technique was developed for quantification and qualification of pseudoephedrine hydrochloride (PSE) in a real sample, which was based on electrochemical sensors and molecular imprinted polymer (MIP). The carbon paste electrode (CPE) was modified and optimized by a different ratio of MIP. MIP/CPE was used as the extraction and working electrode. Differential pulse voltammetry (DPV) method was utilized for measurement. The MIP (molecularly imprinted polymer) and NIP (non-imprinted polymer) were synthesized by various ratios of functional monomer (methacrylic acid) and cross-linker (ethylene glycol dimethacrylate) and template (pseudoephedrine hydrochloride). Some parameters such as pH, extraction time, MIP/CP ratio, stirring rate, and concentration of sample were optimized, and under these conditions, the oxidation peak current was proportional to the pseudoephedrine hydrochloride concentration over a range of 10-500 µM with the coefficient of determination 0.992 (R2). The limit of detection (LOD) was found about 0.274 µM and the limit of quantification (LOQ) was located about 0.825 µM. The relative standard deviation (RSD) was about 1.17%. The results indicated that the modified electrode had a specific ability in selective extraction of pseudoephedrine hydrochloride. | ||
کلیدواژهها | ||
Molecular imprinted polymer؛ Carbon paste modified electrode؛ Pseudoephedrine hydrochloride؛ Voltammetric sensor | ||
مراجع | ||
[1]. D. Josefson, Br. Med. J., 312, 1378 (1996). [2]. H. Doyle, M. Kargin, Br. Med. J.,313, 756 (1996). [3]. S.L. Nightingale, J. Am. Med. Assoc., 275, 1533 (1996). [4]. J. Macek, P. Ptacek, J. Klima, J. Chromatogr., B, 832, 169 (2006). [5]. J. Gunn, S. Kriger, A.R. Terrell, Methods Mol. Biol., 603, 37 (2010). [6]. S.V. Raj, S.U. Kapadia, A.P. Argekar, Talanta, 46, 221 (1998). [7]. O.A. Ismaiel, M.S. Halquist, M.Y. Elmamly, A. Shalaby, H.T. Karnes, J.Chromatogr., 859, 84 (2007). [8]. H. S. Amlashi, A. P. Daryasari, M. Soleimani, S. Afr. J. Chem., 72, 32 (2019). [9]. H. Mahgoub, A. Gazy, F.A. Elyazbi, M.A. Elsayed, R.M. Youssef, J. Pharm. Biomed. Anal., 31, 801 (2003). [10]. Z.R. Tan, D.S. Ouyang, G. Zhou, L.S. Wang, Z. Li, D. Wang, H.H. Zhou, J. Pharm. Biomed. Anal., 42, 207 (2006). [11]. G.B. Li, Z.P. Zhang, X.G. Chen, Z.D. Hu, Z.F. Zhao, M. Hooper, Talanta, 48, 1023 (1999). [12]. C.L. Flurer, L.A. Lin, R.D. Satzger, K.A. Wolnik, J. Chromatogr., 669, 133 (1995). [13]. J.Y. Zhang, J.P. Xie, J.Q. Liu, J.N. Tian, X.G. Chen, Z.D. Hu, Electrophoresis, 25, 74 (2004). [14]. J.P. Xie, J.Y. Zhang, J.Q. Liu, J.N. Tian, X.G. Chen, Z.D. Hu, J. Sep. Sci., 27, 1211 (2004). [15]. X.H. Yang, X.C. Wang, X.M. Zhang, Anal. Chim. Acta., 549, 81 (2005). [16]. Y.T. Iwata, A. Garcia, T. Kanamori, H. Inoue, T. Kishi, I.S. Lurie, Electrophoresis, 23(9), 1328 (2002). [17]. G. Wulff, A. Sarhan, K. Zabrocki, Tetrahedron Lett., 14, 4329 (1973). [18]. L. Andersson, B. Sellergren, K. Mosbach, Tetrahedron Lett., 25, 5211 (1984). [19]. L. Yongqin, L. Zhixing, T. Tianwei, F. Wei, Q. Peiyong, L. Cong, Sensors and Actuators, 133, 15 (2008). [20]. L. Ye., K. Haupt, Anal. Bioanal. Chem., 378, 1887 (2004). [21]. R.I. Boysen, J. Sep. Sci., 42, 51 (2019). [22]. P. Lulinski, A review, Korean J. Couns. Psychother., 76, 1344 (2017). [23]. A. Belmont, S. Jaeger, D. Knopp, R. Niessner, G. Gauglitz, K. Haupt, Biosens. Bioelectron, 22, 3267 (2007). [24]. N. Kirsch, H. Dahlstrom, H. Henschel, M. J. Whitcombe, S. Wikman, I. A. Nicholls, J. Mol. Catal., 58, 110 (2009). [25]. M. Javanbakht, S.E. Fard, A. Mohammadi, M. Abdouss, M. R. Ganjali, P. Norouzi, L. Safaraliee, Anal. Chim. Acta, 612, 65 (2008). [26]. F. Puoci, M. Curcio, G. Cirillo, F. Iemma, J. Food Chem., 106, 836 (2008). [27]. E. Ghasemi, M. Ramezani, J. A. C. R., 13, 36 (2019). [28]. F. Khalilian, H. Soori, J. A. C. R., 11, 65 (2017). [29]. S.Z. Bajwa, R. Dumler, P.A. Lieberzeit, Sensor actuat. B-chem., 192, 522 (2014). [30]. W. Cheng, H. Ma, L. Zhang, Y. Wang, Hierarchically A. Talanta, 127, 255 (2014). [31]. A.L. Hillberg, K.R. Brain, C.J. Allender, Adv. Drug. Deliv. Rev., 57, 1875 (2005). [32]. S.A. Piletsky, S. Subrahmanyam, A.P.F. Turner, Sensor Rev., 21, 292 (2001). [33]. S.A. Piletsky, A.P.F. Turner, Electroanalysis, 14, 317 (2002). [34]. W.M. Mullett, M. Walles, K. Levsen, J. Borlak, J. Pawliszyn, J. Chromatogr., B, 801, 297 (2004). [35]. S. Sadeghi, A. Motaharian, Materials Science and Engineering, 33, 4884 (2013). [36]. M. Giahi, M. Arvand, M. Mirzaei, M.A. Bagherinia, Anal. Lett., 42, 870 (2009). [37]. S.I.M. Zayed, Y.M. Issa, A. Hussein, Ann. Chim., 96, 421 (2006). [38]. H. Ahmar, A.R. Fakhari, Anal. Methods, 4, 812 (2012). | ||
آمار تعداد مشاهده مقاله: 227 تعداد دریافت فایل اصل مقاله: 209 |