تعداد نشریات | 418 |
تعداد شمارهها | 9,997 |
تعداد مقالات | 83,560 |
تعداد مشاهده مقاله | 77,800,512 |
تعداد دریافت فایل اصل مقاله | 54,843,315 |
Presenting a New Fault Current Limiter Structure to Reduce the Over-voltage of the DFIG DC Link in the Voltage Sag Condition | ||
Journal of Applied Dynamic Systems and Control | ||
دوره 5، شماره 2، اسفند 2022، صفحه 1-5 اصل مقاله (1.54 M) | ||
نوع مقاله: Original Article | ||
نویسندگان | ||
Mohsen Ghorbani1؛ Babak Mozafari2؛ Mehdi Firouzi* 3؛ Farzad Golshan1 | ||
1Department of Electrical Engineering, Karaj Branch, Islamic Azad University, Karaj, Iran | ||
2Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran | ||
3Department of Electrical Engineering, Abhar Branch, Islamic Azad University, Abhar, Iran | ||
چکیده | ||
In this study a new type of fault current limiter is introduced. It has been named multi-functional capacitive fault current limiter (MCFCL). as a variable capacitor, its function is to control active power flow in normal conditions as well as improving the capability of low voltage rid-through (LVRT) in fault operating conditions. The new structure has been proposed based on the capacitive bridge-type fault current limiter (BFCL) and the RL-type fault current limiter (FCL), which is modified to enhance low-voltage ride-through capability. To assess the efficacy of proposed fault current limiter, the time domain simulations were executed in PSCAD/EMTDC software and its function is compared with the RL-type SSFCLs in normal and symmetrical or asymmetrical fault conditions. Also its efficacy has been evaluated in a fixed speed based wind farm. The result of simulations showed that the MCFCL is not only able to control the power flow in normal operating condition, but also improves the LVRT performance in fault operating condition in the wind farms. | ||
کلیدواژهها | ||
Wind Farm؛ Multi-Functional Capacitive Fault Current Limiter؛ Transmission Line | ||
مراجع | ||
[1] Transmission Code. Network and System Rules of the German Transmission System Operators, Verband der Netzbetreiber VDNe.v. beim BDEW. [Online]. Available: www.bdew.de/ Aug. 2007 [2] F. Iov, A. D. Hansen, P. Sørensen, and N. A. Cutululis, “Mapping of grid faults and grid codes,” Risø Nat. Lab., Tech. Univ. Denmark, Copenhagen, Denmark, Rep. Risø-R-1617-(EN), Jul. 2007 [3] J. Lopez, P. Sanchis, X. Roboam, and L. Marroyo, “Dynamic Behavior of the Doubly Fed Induction Generator During Three Phase Voltage Dips,” IEEE Trans. Energy Convers,2007, 22(3), pp. 709-717 [4] M. Rahimi and M. Parniani, “Transient Performance Improvement of Wind Turbines With Doubly Fed Induction Generators Using Nonlinear Control Strategy”, IEEE Trans. Energy Convers,2010, 25(2), pp. 514-525 [5] C. Wessels, N. Hoffmann, M. Molinasr, and F. Wilhelm Fuchs.: ‘STATCOM Control at Wind Farms With Fixed- Speed Induction Generators Under Asymmetrical Grid Faults’. IEEE Transactions on Industrial Electronics, 2013, 60(7), pp. 2864 – 2873 [6] J.A. Suul, M. Molinas, T. Undeland.: ‘STATCOMBased Indirect Torque Control of Induction Machines During Voltage Recovery After Grid Faults’, IEEE Transactions on Power Electronics, 2010, 25(5), pp. 1240- 1250 [7] A. Causebrook, D. J. Atkinson, and A. G. Jack.: ‘Fault Ride-Through of Large Wind Farms Using Series Dynamic Braking Resistors’, IEEE Transaction on Power System, 2007, 22(3), pp. 966 – 975 [8] P. Huang, M. Sh. El Moursi, S. A. Hasen.: ‘Novel Fault Ride-Through Scheme and Control Strategy for Doubly Fed Induction Generator-Based Wind Turbine’, IEEE Transactions on Energy Conversion, 2015, 30(2), pp. 635 – 645 [9] L. Huchel, M. S. El Moursi , H. H. Zeineldin.: ‘A Parallel Capacitor Control Strategy for Enhanced FRT Capability of DFIG’, IEEE Transactions on Sustainable Energy , 2015, 6(2), pp. 303 – 312 [10] Kh. Goweily, M. Sh. El Moursi, M. Abdel-Rahman, M. A. L. Badr.: ‘Voltage booster scheme for enhancing the fault ride-through of wind turbines’, IET Power Electronics, 2015, 8(10), pp. 1853-1863 [11] S. M. Muyeen.: ‘A Combined Approach of Using an SDBR and a STATCOM to Enhance the Stability of a Wind Farm’, IEEE Systems Journal 2015, 9(3), pp. 922–932 [12] S. M. Muyeen, M. H. Ali, R. Takahashi, T. Murata, and J. Tamura.: ‘Transient stability enhancement of wind generator by a new logical pitch controller’, IEEJ Transactions on Power and Energy, 2006, 126(8), pp. 742– 752 [13] M. J. Hossain, H.R. Pota , V. A. Ugrinovskii and R.A.Ramos.: ‘Simultaneous STATCOM and Pitch Angle Control for Improved LVRT Capability of Fixed-Speed Wind Turbines’, IEEE Transactions on Sustainable Energy.,2010, 1(3), pp. 142–151 [14] L. Wang, and Q. S. Vo.: ‘Power Flow Control and Stability Improvement of Connecting an Offshore Wind Farm to a One-Machine Infinite-Bus System Using a SSSC’, IEEE Transactions on Sustainable Energy, 2013, 4(2), pp. 358 - 369 [15] A. E. Leon, M. F. Farias, P. E. Battaiotto, J. A. Solsona.: ‘Control Strategy of a DVR to Improve Stability in Wind Farms Using Squirrel-Cage Induction Generators’, IEEE Transactions on Power System, 2011, 26(3), pp. 1609 – 1617 [16] F. K. A. Lima, A. Luna, P. Rodriguez, E. H. Watanabe, and F. Blaab jerg, “Rotor voltage dynamics in the doubly fed induction generator during grid faults,” IEEE Trans. Power Electron. 2010, 25(1), pp. 118–130 [17] J. Liang, W. Qiao, and R. G. Harley, “Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines,” IEEE Trans. Energy Convers. 2010, 25(3), pp. 836–843 [18] J. Yao, H. Li, Y. Liao, and Z. Chen, “An improved control strategy of limiting theDC-link voltage fluctuation for a doubly fed induction wind generator,” IEEE Trans. Power Electron. 2008, 23(3), pp. 1205–1213 [19] A. R. Fereidouni, B. Vahidi and T. Hosseini Mehr, "The Impact of Solid State Fault Current Limiter on Power Network With Wind-Turbine Power Generation," in IEEE Transactions on Smart Grid, 2013, 4(2), pp. 1188-1196. | ||
آمار تعداد مشاهده مقاله: 92 تعداد دریافت فایل اصل مقاله: 127 |